Published January 1991 | Version v1
Journal article

Cone penetrometer tests and HydroPunch sampling: A screening technique for plume definition

  • 1. EMCON Associates, San Jose, CA (United States)

Description

Cone penetrometer tests and HydroPunch sampling were used to define the extent of volatile organic compounds in ground water. The investigation indicated that the combination of the these techniques is effective for obtaining ground water samples for preliminary plume definition. HydroPunch samples can be collected in unconsolidated sediments and the analytical results obtained from these samples are comparable to those obtained from adjacent monitoring wells. This sampling method is a rapid and cost-effective screening technique for characterizing the extent of contaminant plumes in soft sediment environments. Use of this screening technique allowed monitoring wells to be located at the plume boundary, thereby reducing the number of wells installed and the overall cost of the plume definition program

Additional details

Publishing Information

Journal Title
Ground Water Monitoring Review
Journal Volume
11
Journal Issue
2
Series
Ground Water Monit. Rev.
Journal Page Range
101-106
ISSN
0277-1926
CODEN
GWMRD