Non reflecting boundary conditions and their use in estimating the effects of coolant channel failure in a PHWR

  • 1. Indian Inst. of Technol., Munbai (India). Dept. of Mech. Eng.

Description

Non reflecting boundary conditions are applied to the truncation boundary of large domains to restrict the domain to a small region of interest from which waves travel only outwards. In this paper, this procedure is used to calculate the pressure field in the moderator of a pressurized heavy water reactor after a coolant channel has failed. Non reflecting boundary conditions are applied to the moderator boundary while a perfectly reflecting boundary is assumed for the channels. (orig.)

Additional details

Publishing Information

Journal Title
Nuclear Engineering and Design
Journal Volume
188
Journal Issue
3
Journal Page Range
p. 345-360
ISSN
0029-5493
CODEN
NEDEAU

Optional Information

Notes
8 refs.