Experience Using DosimetryCheck software for IMRT and RapidArc Patient Pre-treatment QA and a New Feature for QA during Treatment
Description
We have used the DosimetryCheck program with the EPID's on our Varian 2100EX's to perform pre-treatment QA on more than 350 patients, between the last quarter of 2006 and the present. The software uses the EPID measured fluences of the treatment fields to reconstruct the dose distribution in the CT planning model of the patient. Since the dose calculation algorithm, is different from that used by our Eclipse planning system, this provides an independent check of planning accuracy as well as treatment delivery. 2D and 3D dose distributions, point doses, Gamma distributions, DVH statistics and MU calculations can be compared. Absolute differences of Reference Point doses between Dosimetry Check and Eclipse average 1.20%, which is similar to the ionization chamber dose differences of 1.29% for the same patient verification plans. Examples of cases for various treatment sites and delivery modes will be presented. A Special Report in Medical Physics Vol. 37 Number 6 Pg. 2638-2644 from Mans et al at The Netherlands Cancer Institute demonstrated the ability of in vivo EPID dosimetry to detect treatment errors, that escaped other QA checks. A new version of DosimetryCheck awaiting FDA approval, is capable of successfully reconstructing the dose distribution in the patient from the EPID measured exit fluences. This can also be applied to CBCT images providing actual patient dose verification for a treatment session. This should be particularly useful for monitoring hypo-fractionated treatment regimens. Examples of this method will also be presented.
Availability note (English)
Available from http://dx.doi.org/10.1088/1742-6596/250/1/012101Additional details
Identifiers
Publishing Information
- Journal Title
- Journal of Physics. Conference Series (Online)
- Journal Volume
- 250
- Journal Issue
- 1
- Journal Page Range
- [5 p.]
- ISSN
- 1742-6596
Conference
- Title
- 6. international conference on 3D radiation dosimetry
- Acronym
- IC3DDose
- Dates
- 22-26 Aug 2010
- Place
- Hilton Head Island, SC (United States)
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 42053615
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ACCURACY; ALGORITHMS; COMPUTER CODES; DELIVERY; DISTRIBUTION; DOSIMETRY; IMAGES; IN VIVO; IONIZATION CHAMBERS; NEOPLASMS; PATIENTS; PLANNING; RADIATION DOSE DISTRIBUTIONS; VERIFICATION
- Descriptors DEC
- DISEASES; MATHEMATICAL LOGIC; MEASURING INSTRUMENTS; RADIATION DETECTORS