Published 1995 | Version v1
Miscellaneous Open

Ultrasonic systems for high-accuracy thickness measurement of fuel bundle bearing pads and shield plug crimps

  • 1. Ontario Hydro, Toronto, ON (Canada)

Description

The performance of two ultrasonic systems, remotely operated in high radiation environment, are presented. The first system is used to measure the bearing pad height of radioactive fuel bundles located in the irradiated fuel bays, at Darlington NGS. The system was designed and commissioned to achieve an accuracy of ± 20 μm. The repeatability of results is within ± 10 μm uniformity band. The measurements are independent of testing speed, water temperature, bundle temperature, pencil geometry. Possibilities and limitations of the UT system are also presented and some improved alternatives are proposed. The second system was developed for measuring the crimp height of shield plugs (special iron casting) at Bruce B - Mark Ill development. The accuracy of measurements is ± 50 μm, with a repeatability of ± 25 μm. The results are independent of shield plug thickness variation and ovality, crimp off-set and heavy-water temperature. (author)

Files

29054833.pdf

Files (172.0 kB)

Name Size Download all
md5:05e9eb4d7ec5a873a162fbbef637591a
172.0 kB Preview Download
Part of:
Proceedings of the third international conference on CANDU maintenance

Additional details

Publishing Information

Imprint Title
Proceedings of the third international conference on CANDU maintenance
Imprint Pagination
473 p.
Journal Page Range
p. 405-408
Report number
INIS-CA--0018

Conference

Title
3. International conference on CANDU maintenance
Dates
19-21 Nov 1995
Place
Toronto, ON (Canada)

Optional Information

Notes
10 figs.