Published 1983
| Version v1
Report
Open
Periodic large-amplitude thermal oscillations occurring in a buoyant plume
Description
Reactor events such as N-1 loop operation in conjunction with a leaky check valve in the down loop can cause flow to be convected back into the reactor outlet nozzle/piping region and to be back-flushed into the reactor outlet plenum. The preceding results in a temperature difference between pipe inflow and plenum. This temperature difference causes buoyancy forces which if large enough can cause: a pipe backflow and recirculation loop; and a thermal plume in the plenum. Both phenomena are being studied because they can produce undesirable pipe, nozzle and plenum wall thermal distributions, and hence undesirable thermal stresses. This paper discusses some features of the plume
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01; 1 as DE83014812.Files
15002995.pdf
Files
(117.9 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:b15b9b10e0f79b4647810093b669a3a1
|
117.9 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 6 p.
- Report number
- CONF-831047--70-Summ
Conference
- Title
- American Nuclear Society winter meeting.
- Dates
- 30 Oct - 4 Nov 1983.
- Place
- San Francisco, CA (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 15002995
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- HEAT TRANSFER; HYDRAULICS; LEAKS; NOZZLES; PIPES; POWER REACTORS; PRIMARY COOLANT CIRCUITS; REACTOR SAFETY; TESTING; THERMAL STRESSES; VALVES
- Descriptors DEC
- CONTROL EQUIPMENT; COOLING SYSTEMS; ENERGY TRANSFER; EQUIPMENT; FLOW REGULATORS; REACTOR COMPONENTS; REACTOR COOLING SYSTEMS; REACTORS; SAFETY; STRESSES