Published 2003 | Version v1
Miscellaneous Open

Changes of the main parameters of the primary heat transport system of the Embalse NPP after the replacement of the divider plates of the steam generators

  • 1. Nucleoelectrica Argentina SA (NASA), Embalse (Argentina). Central Nuclear Embalse

Description

Divider plates of the four steam generators were repaired at Embalse NPP during the outage of 2002. This task led to a reduction of heavy water by-pass from the hot to the cold side. As a consequence of this, some Primary Heat Transport System (PHTS) parameters were affected. The main results of this work are the following: a) Bulk PHTS flow did not change significantly; b) Inlet Header temperature dropped 2,8 C degrees at full power; c) Quality at Outlet Header is now practically negligible. (author)

Availability note (English)

Available from INIS in electronic form

Files

35070239.pdf

Files (195.8 kB)

Name Size Download all
md5:55c503b3c3aa3e04dd1831f94c1879e1
195.8 kB Preview Download

Additional details

Additional titles

Original title (Spanish)
Cambio en los parametros significativos del SPTC de la CNE ante el reemplazo de las placas divisorias de los generadores de vapor

Publishing Information

Publisher
AATN
Imprint Place
Buenos Aires (Argentina)
Imprint Pagination
4 p.
Report number
INIS-AR-C--363

Conference

Title
30. Annual meeting of the Argentine Association of Nuclear Technology
Original Conference Title
AATN 2003: 30. Reunion anual de la Asociacion Argentina de Tecnologia Nuclear (AATN)
Acronym
AATN 2003
Dates
26 Nov 2003
Place
Buenos Aires (Argentina)

Optional Information

Notes
3 refs., 4 figs.