Published February 1983 | Version v1
Journal article

Gold-195m, an ultra-short-lived generator-produced radionuclide: clinical application in sequential first pass ventriculography

  • 1. Harbor-UCLA Medical Center, Torrance, CA

Description

Gold 195m (Au-195m) has a half-life of 30.5 sec and can be produced at the bedside from the parent mercury-195m (T 1/2 . 41.6 hr). The generator produced sterile pyrogen-free Au-195m with mercury breakthrough of 0.75 +/- 0.09 (s.e.m.) muCi per mCi of Au-195m. Approximately 20 to 25 mCi of Au-195m was produced per elution from a generator containing 155 mCi of Hg-195m. The authors compared first-pass resting Tc-99m angiograms with Au-195m angiograms in 28 patients. The correlation coefficient between the two studies was 0.92 over an ejection-fraction range from 0.22 to 0.83. In addition, they tested the reproducibility of Au-195m first-pass angiograms by performing two studies 3 min apart. In 25 patients with ejection fractions ranging from 0.20 to 0.78, the correlation coefficient between such pairs was 0.93. The nuclide is reliably and reproducibly produced, and its short half-life allows the performance of background-free sequential first-transit studies with unusually low radiation exposure to the patient

Additional details

Publishing Information

Journal Title
J. Nucl. Med.
Journal Volume
24
Journal Issue
2
Series
J. Nucl. Med.
Journal Page Range
139-144
ISSN