Helium/solid powder O-ring leakage correlation experiments using a radiotracer
Description
UO2 definitely leaked past the O-ring in three of the tests confirming the major results of the previous work. Continuous leakage at these levels may require additional precautions under present regulatory policies. The mechanism and the time and particle size dependence for the leakage are not known, but there is some indication leakage is more likely at low temperatures. It is possible leakage is due to movement of the O-ring during temperature or pressure cycling at the beginning or end of a test. The radiotracer method involves less labor and is much less susceptible to contamination than the previous method. Future work will investigate leakage past lubricated O-rings and time dependence of leakage. 1 reference, 1 table
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01 as DE84005518.Files
15064459.pdf
Files
(91.1 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:a157cf9b8313623e3a4c3b026ebc0ef1
|
91.1 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 7 p.
- Report number
- CONF-840614--10
Conference
- Title
- Annual meeting of the American Nuclear Society.
- Dates
- 3-8 Jun 1984.
- Place
- New Orleans, LA (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 15064459
- Subject category
- S42: ENGINEERING; S42: ENGINEERING;
- Resource subtype / Literary indicator
- Conference, Numerical Data
- Descriptors DEI
- CASKS; CORRELATIONS; EXPERIMENTAL DATA; GAMMA DETECTION; HELIUM; LEAK TESTING; LEAKS; POWDERS; SEALS; TRACER TECHNIQUES; URANIUM DIOXIDE
- Descriptors DEC
- ACTINIDE COMPOUNDS; CHALCOGENIDES; CONTAINERS; DATA; DETECTION; ELEMENTS; INFORMATION; ISOTOPE APPLICATIONS; NONMETALS; NUMERICAL DATA; OXIDES; OXYGEN COMPOUNDS; RADIATION DETECTION; RARE GASES; TESTING; URANIUM COMPOUNDS; URANIUM OXIDES