Published 1984 | Version v1
Report Open

Helium/solid powder O-ring leakage correlation experiments using a radiotracer

Description

UO2 definitely leaked past the O-ring in three of the tests confirming the major results of the previous work. Continuous leakage at these levels may require additional precautions under present regulatory policies. The mechanism and the time and particle size dependence for the leakage are not known, but there is some indication leakage is more likely at low temperatures. It is possible leakage is due to movement of the O-ring during temperature or pressure cycling at the beginning or end of a test. The radiotracer method involves less labor and is much less susceptible to contamination than the previous method. Future work will investigate leakage past lubricated O-rings and time dependence of leakage. 1 reference, 1 table

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01 as DE84005518.

Files

15064459.pdf

Files (91.1 kB)

Name Size Download all
md5:a157cf9b8313623e3a4c3b026ebc0ef1
91.1 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
7 p.
Report number
CONF-840614--10

Conference

Title
Annual meeting of the American Nuclear Society.
Dates
3-8 Jun 1984.
Place
New Orleans, LA (USA).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
15064459
Subject category
S42: ENGINEERING; S42: ENGINEERING;
Resource subtype / Literary indicator
Conference, Numerical Data
Descriptors DEI
CASKS; CORRELATIONS; EXPERIMENTAL DATA; GAMMA DETECTION; HELIUM; LEAK TESTING; LEAKS; POWDERS; SEALS; TRACER TECHNIQUES; URANIUM DIOXIDE
Descriptors DEC
ACTINIDE COMPOUNDS; CHALCOGENIDES; CONTAINERS; DATA; DETECTION; ELEMENTS; INFORMATION; ISOTOPE APPLICATIONS; NONMETALS; NUMERICAL DATA; OXIDES; OXYGEN COMPOUNDS; RADIATION DETECTION; RARE GASES; TESTING; URANIUM COMPOUNDS; URANIUM OXIDES