Published 1987
| Version v1
Report
Open
PRAAGE: An interactive IBM-PC code for unreliability/aging analysis
Description
The more redundant a system is, the faster its unavailability increases with aging. Normally a highly redundant system has a small unavailability contribution, but aging may make it significant. This is due to the fact that, as assumed in this study, aging degradation drives up the failure rate of all redundant trains and causes a rapid loss in the effectiveness of the redundancy in reducing the unavailability. Thus aging, if allowed to cross trains, can be a significant contributor to unavailability. This conclusion demonstrates the usefulness of PRAAGE for interactive systems analysis. 3 refs., 1 fig., 1 tab
Availability note (English)
Available from NTIS, PC A02/MF A01; 1 as DE87012124.Files
19023257.pdf
Files
(100.2 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:1fb7739580d857ca430f1319fcca253e
|
100.2 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 6 p.
- Report number
- BNL-NUREG--39923
Conference
- Title
- Joint meeting of the American Nuclear Society and the Atomic Industrial Forum.
- Dates
- 15-19 Nov 1987.
- Place
- Los Angeles, CA (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 19023257
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS; S99: GENERAL AND MISCELLANEOUS;
- Resource subtype / Literary indicator
- Conference, Numerical Data
- Descriptors DEI
- AGING; AVAILABILITY; COMPUTERIZED SIMULATION; COMPUTERS; NUCLEAR POWER PLANTS; P CODES; PROBABILISTIC ESTIMATION; PUMPS; REACTOR COMPONENTS; RELIABILITY; SYSTEMS ANALYSIS; THEORETICAL DATA
- Descriptors DEC
- COMPUTER CODES; DATA; EQUIPMENT; INFORMATION; NUCLEAR FACILITIES; NUMERICAL DATA; POWER PLANTS; SIMULATION; THERMAL POWER PLANTS
Optional Information
- Notes
- Portions of this document are illegible in microfiche products.
- Secondary number(s)