Published December 2017 | Version v1
Book

Efficiency study of RPC detector in drastic environment

  • 1. Department of Physics, Institute of Science, Banaras Hindu University, Varanasi (India)

Description

In this article, we performed the experiment to study the efficiency of the glass electrodes base RPC detector under any drastic circumstances such as failure of electric power, huge jump in the relative humidity etc. Such kind of scenario may be possible during the operation of INO-ICAL. We performed this study along with the use of Silicon Fiber Sheet based pickup panel. We are aware that relative humidity changes when temperatures change. Because warm air can hold more water vapor than cool air, therefore, relative humidity falls when the temperature rises, if no moisture is added to the air. The dew point is the temperature at which a given sample of air will have a relative humidity of 100%; hence, the saturation temperature. Some study, in a limited range of temperature and humidity has been done for the performance of the RPC detector

Part of:
Proceedings of the DAE-BRNS symposium on nuclear physics. V. 62

Additional details

Publishing Information

Publisher
Bhabha Atomic Research Centre
Imprint Place
Mumbai (India)
Imprint Title
Proceedings of the DAE-BRNS symposium on nuclear physics. V. 62
Imprint Pagination
[1220 p.]
Journal Page Range
p. 1138-1139

Conference

Title
62. DAE-BRNS symposium on nuclear physics
Dates
20-24 Dec 2017
Place
Patiala (India)

INIS

Country of Publication
India
Country of Input or Organization
India
INIS RN
49014862
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CALORIMETERS; ELECTRODES; HUMIDITY; NEUTRINO OSCILLATION; PERFORMANCE; WIMPS
Descriptors DEC
ELEMENTARY PARTICLES; MEASURING INSTRUMENTS; MOISTURE; POSTULATED PARTICLES

Optional Information

Notes
2 refs., 3 figs.