Published December 1991 | Version v1
Report

Standardization of the cumulative absolute velocity

  • 1. Yankee Atomic Electric Co., Bolton, MA (United States)

Description

EPRI NP-5930, ''A Criterion for Determining Exceedance of the Operating Basis Earthquake,'' was published in July 1988. As defined in that report, the Operating Basis Earthquake (OBE) is exceeded when both a response spectrum parameter and a second damage parameter, referred to as the Cumulative Absolute Velocity (CAV), are exceeded. In the review process of the above report, it was noted that the calculation of CAV could be confounded by time history records of long duration containing low (nondamaging) acceleration. Therefore, it is necessary to standardize the method of calculating CAV to account for record length. This standardized methodology allows consistent comparisons between future CAV calculations and the adjusted CAV threshold value based upon applying the standardized methodology to the data set presented in EPRI NP-5930. The recommended method to standardize the CAV calculation is to window its calculation on a second-by-second basis for a given time history. If the absolute acceleration exceeds 0.025g at any time during each one second interval, the earthquake records used in EPRI NP-5930 have been reanalyzed and the adjusted threshold of damage for CAV was found to be 0.16g-set

Availability note (English)

Research Reports Center, PO Box 50490, Palo Alto, CA 94303.

Additional details

Additional titles

Subtitle (English)
Final report

Publishing Information

Imprint Pagination
14 p.
Report number
EPRI-TR--100082

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
23031748
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Resource subtype / Literary indicator
Non-conventional Literature
Quality check status
Yes
Descriptors DEI
ACCELERATION; DESIGN BASIS ACCIDENTS; EARTHQUAKES; GROUND MOTION; NUCLEAR POWER PLANTS; SEISMIC EFFECTS;
Descriptors DEC
ACCIDENTS; MOTION; NUCLEAR FACILITIES; POWER PLANTS; REACTOR ACCIDENTS; THERMAL POWER PLANTS;