Published December 1977 | Version v1
Journal article

Failure to detect circulating DNA-anti-DNA complexes by four radioimmunological methods in patients with systemic lupus erythematosus

  • 1. Hopital Cantonal Geneve (Switzerland)

Description

The presence of DNA-anti-DNA complexes in sera from patients with systemic lupus erythematosus (SLE) was investigated by two new radioimmunoassays (RIA) developed for this purpose and by measuring the CLq and DNA binding activity of serum before and after treatment with DNAse. Two direct RIA developed in this study were based on the reactivity of [3H]actinomycin D ([3H]ACT-D) or solid-phase methylated bovine serum albumin (mBSA) with DNA-anti-DNA complexes. DNA-anti-DNA complexes prepared in vitro could be efficiently detected at various antigen-antibody ratios by these two RIA. Increased levels of circulating immune complexes as indicated by the CLq binding test were found in 52% of SLE sera. However, the frequency of specific DNA-anti-DNA complexes detected in SLE sera was very low. Only 6% of sera exhibited an increased value deviating by more than three s.d. from the normal mean when tested with the [3H]ACT-D binding RIA or the solid-phase mBSA RIA. On the other hand, there was no significant difference in the serum CLq or DNA binding activity after treatment with DNAse. These results suggest that DNA-anti-DNA complexes do not occur frequently in circulating blood and represent only a very small portion of the immune complexes detected in serum from patients with SLE. (author)

Additional details

Publishing Information

Journal Title
Clin. Exp. Immunol.
Journal Volume
30
Journal Issue
3
Series
Clin. Exp. Immunol.
Journal Page Range
384-392