Are dilution, slow injection and care bolus technique the causal solution to mitigating arterial-phase artifacts on gadoxetic acid-enhanced MRI? A large-cohort study
Creators
- 1. Department of Biomedical Imaging and Image-Guided Therapy, Medical University, General Hospital of Vienna (AKH), Waehringer Guertel 18-20, 1090, Vienna (Austria)
- 2. Department of Diagnostic and Interventional Radiology, Clinic Donaustadt, Vienna Healthcare Group, Vienna (Austria)
- 3. Department of Diagnostic and Interventional Radiology, Goettlicher Heiland Krankenhaus, Barmherzige Schwestern Krankenhaus, and Sankt Josef Krankenhaus, Vienna (Austria)
- 4. Department of Radiology, Memorial Sloan Kettering Cancer Center, New York City, NY (United States)
- 5. Department of Radiology, Duke University Medical Center, Durham, NC (United States)
Description
Arterial-phase artifacts are gadoxetic acid (GA)-enhanced MRI's major drawback, ranging from 5 to 39%. We evaluate the effect of dilution and slow injection of GA using automated fluoroscopic triggering on liver MRI arterial-phase (AP) acquisition timing, artifact frequency, and lesion visibility. Saline-diluted 1:1 GA was injected at 1 ml/s into 1413 patients for 3 T liver MRI. Initially, one senior abdominal radiologist, i.e., principal investigator (PI), assessed all MR exams and compared them to previous and follow-up images, as well as the radiology report on record, determining the standard of reference for lesion detection and characterization. Then, three other readers independently evaluated the AP images for artifact type (truncation (TA), transient severe motion (TSM) or mixed), artifact severity (on a 5-point scale), acquisition timing (on a 4-point scale) and visibility (on a 5-point scale) of hypervascular lesions ≥ 5 mm, selected by the PI. Artifact score ≥ 4 and artifact score ≤ 3 were considered significant and non-significant artifacts, respectively. Of the 1413 exams, diagnostic-quality arterial-phase images included 1100 (77.8%) without artifacts, 220 (15.6%) with minimal, and 77 (5.4%) with moderate artifacts. Only 16 exams (1.1%) had significant artifacts, 13 (0.9%) with severe artifacts (score 4), and three (0.2%) non-diagnostic artifacts (score 5). AP acquisition timing was optimal in 1369 (96.8%) exams. Of the 449 AP hypervascular lesions, 432 (96.2%) were detected. Combined dilution and slow injection of GA with MR results in well-timed arterial-phase images in 96.8% and a reduction of exams with significant artifacts to 1.1%. Hypervascular lesions, in particular HCC detection, hinge on arterial-phase hyperenhancement, making well-timed, artifact-free arterial-phase images a prerequisite for accurate diagnosis. Saline dilution 1:1, slow injection (1 ml/s), and automated bolus triggering reduce artifacts and optimize acquisition timing.
Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology (Internet)
- Journal Volume
- 34
- Journal Issue
- 8
- Journal Page Range
- p. 5215-5227
- ISSN
- 1432-1084
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 55079749
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- CARCINOMAS; COMPARATIVE EVALUATIONS; DATA COMPILATION; DIAGNOSIS; DILUTION; GADOLINIUM COMPOUNDS; IMAGE PROCESSING; INTRAVENOUS INJECTION; LIVER; NMR IMAGING; RELAXATION TIME; RETENTION; SIGNAL-TO-NOISE RATIO; VASCULAR DISEASES; WEIGHTING FUNCTIONS
- Descriptors DEC
- BODY; CARDIOVASCULAR DISEASES; DATA; DATA PROCESSING; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; DIMENSIONLESS NUMBERS; DISEASES; EVALUATION; FUNCTIONS; GLANDS; INFORMATION; INJECTION; INTAKE; NEOPLASMS; ORGANS; PROCESSING; RARE EARTH COMPOUNDS