SOUTH RAMP DEVIATED ALIGNMENT 3.01.X AREA GROUND SUPPORT ANALYSIS (STATION 71+07.10 TO 71+44.10)

Description

The purpose of the analysis is to provide a basis for ensuring safe conditions in the Case VI area. The scope of this analysis is to analyze and recommend future action for a section of the South Ramp with a deviated alignment, here referred to as Case VI 3.01.X area. This area is located between Stations 71+07.10 to 71+44.10 in the South Ramp of the ESF (Exploratory Studies Facility) Main Loop tunnel. The scope of the analysis includes accomplishing the following goals: (1) Document the as-built configuration including existing voids and installed ground support; (2) Document the geotechnical properties of the rock mass and structural features; and (3) Evaluate the stability and develop recommendations for future action

Availability note (English)

Available from INIS in electronic form; Also available from OSTI as DE00861096; PURL: https://www.osti.gov/servlets/purl/861096-bSf6bM/

Files

37046767.pdf

Files (7.2 MB)

Name Size Download all
md5:3f9980adee8b1e67be829f973b4230ea
7.2 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
65 p.
Report number
BAB--000000-01717-0200-00156