Published July 1997 | Version v1
Journal article

Validation of BATAN's standard diffusion codes on IAEA benchmark static calculation

  • 1. National Atomic Energy Agency, Serpong (Indonesia). Multipurpose Reactor Center

Description

Extensive benchmark calculations using the combination of BATAN's standard diffusion code and WIMS/D4 have been conducted to check the validity and accuracy of the codes, and to obtain proper cell modeling for MTR type fuel and control elements which will be used in designing the next high loading silicide fuel of RSG-GAS. The benchmark object and parameters to be calculated are defined by the IAEA in the IAEA-TECDOC-233 and IAEA-TECDOC-643. In general, the combination of BATAN's standard diffusion code, BATAN-2DIFF, and WIMS/D4 gave very satisfactory results which proved the validity of the proposed WIMS/D4 cell model and the accuracy of the BATAN's diffusion code used in the benchmark calculations. Four-energy-group, multi plate options of WIMS/D4 were sufficient to give accurate results in term of infinite multiplication factors, fuel depletion results and diffusion constants for whole core calculations. Two-dimensional, four-group diffusion model supplied with a correct axial buckling value can be considered accurate enough for the MTR whole core calculations. (author) 10 refs, 7 tabs, 6 figs

Additional details

Publishing Information

Journal Title
Atom Indonesia
Journal Volume
23
Journal Issue
2
Journal Page Range
p. 73-91.
ISSN
0126-1568
CODEN
ATINDD