Published December 2018
| Version v1
Journal article
Demonstration of Ameliorate Volumetric Testing in Safe End Welds
Creators
- 1. Fujian Fuqing Nuclear Power Co. Ltd., Technical Support Department, Fuqing (China)
Description
The main pump used in some nuclear plant has safe ends between the main pump and the main pipe. This paper has studied ultrasonic and radiographic testing techniques. RSE-M and ASME standards were analyzed comparatively, and the engineering practice factors were also discussed. It is proved that UT is accurate, continuous and economical for in-service inspection and supervision of the main pump safe ends crack which is the most common and dangerous. (authors)
Additional details
Identifiers
Publishing Information
- Journal Title
- Nuclear Power Engineering
- Journal Volume
- 39
- Journal Issue
- S2
- Journal Page Range
- p. 157-159
- ISSN
- 0258-0926
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 54087586
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- CRACKS; ENGINEERING; IN-SERVICE INSPECTION; NUCLEAR POWER PLANTS; PIPES; PUMPS; STANDARDS; TESTING; ULTRASONIC WAVES; WELDED JOINTS
- Descriptors DEC
- EQUIPMENT; INSPECTION; JOINTS; NUCLEAR FACILITIES; POWER PLANTS; SOUND WAVES; THERMAL POWER PLANTS; TUBES
Optional Information
- Notes
- 2 refs.; http://dx.doi.org/10.13832/j.jnpe.2018.S2.0157