Published July 1976 | Version v1
Journal article

Calculated neutron dose rates and flux densities from implantable Californium-252 point and line sources

  • 1. Department of Chemical and Nuclear Engineering, and Department of Radiology, University of Cincinnati, Cincinnati, Ohio 45221

Description

The results of neutron-transport flux-density and dose rate calculations for implantable Cafornium-252 point and line sources in essentially infinite tissue-equivalent material are presented. The point-source flux densities were obtained from a discrete ordinates calculation, and the point dose rates were established by multiplying the flux densities by their appropriate kerma factors. Line-source dose rates were evaluated by integrating the point dose rates over the length of the line source. Dose-rate data are given within a 20 x 20-cm region from the source center for source lengthS of 1.5, 2, and 3 cm. The dose rates established by these calculations showed good agreement with an independent Monte Carlo calculation. Detailed point-source flux-density data as a function of energy and position are also given

Additional details

Identifiers

Publishing Information

Journal Title
Medical Physics
Journal Volume
3
Journal Issue
4
Series
Med. Phys.
Journal Page Range
241-247
ISSN
0094-2405

Optional Information

Notes
Updated automatically by Metadata and Full-Text Enrichment Agent