Published March 2014
| Version v1
Journal article
Analysis of the impact of accident temperature environment on pressure transmitter in nuclear power plant
Creators
- 1. Hunan Provincial Key Laboratory of Emergency Safety Technology and Equipment for Nuclear Facilities, Hengyang (China)
- 2. School of Nuclear Science and Technology, University of South China, Hengyang (China)
Description
Pressure transmitters are widely used in measuring of process parameters in nuclear power plant. Most of the pressure transmitters located in containment vessel have passed the DBA qualification, but whether they could survive in high-temperature environment in DBDA is unknown. In this article, we made analysis about the characteristics of pressure transmitter, and used both envelope and simulation methods to study how temperature affects the transmitter in DBA and BDBA condition. At last, we gave some suggestions on way of improving the resistance to elevated temperature of transmitter according to the study. (authors)
Additional details
Publishing Information
- Journal Title
- Journal of Nanhua University. Science and Technology
- Journal Volume
- 28
- Journal Issue
- 1
- Journal Page Range
- p. 1-4, 16
- ISSN
- 1673-0062
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 50061419
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; S54: ENVIRONMENTAL SCIENCES;
- Descriptors DEI
- BEYOND-DESIGN-BASIS ACCIDENTS; CONTAINMENT; NUCLEAR POWER PLANTS; SIMULATION; TEMPERATURE RANGE 0400-1000 K
- Descriptors DEC
- ACCIDENTS; NUCLEAR FACILITIES; POWER PLANTS; TEMPERATURE RANGE; THERMAL POWER PLANTS
Optional Information
- Notes
- 3 figs., 1 tab., 10 refs.