Published September 2010 | Version v1
Miscellaneous

Determination of the dose around an ovoid for treatments in intracavitary brachytherapy Hdr

  • 1. IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Legaria No. 694, Col. Irrigacion, 11500 Mexico D. F. (Mexico)
  • 2. Hospital Central Militar, Periferico y Ejercito Nacional s/n, Lomas de Sotelo, 11200 Mexico D. F. (Mexico)
  • 3. Hospital Juarez de Mexico, Av. Instituto Politecnico Nacional No. 5190, Col. Magdalena de las Salinas, 03220 Mexico D. F. (Mexico)
  • 4. Universidad Autonoma Metropolitana, Unidad Iztapalapa, Av. San Rafael Atlixco No. 186, Col. Vicentina, 09340 Mexico D. F. (Mexico)

Description

On this work the results of the dosimetric measurements are presented around an ovoid of 2 cm diameter. The measurements were carried out using a water mannequin, an ovoid, a radiation gamma source of 192Ir and thermoluminescent dosemeters. The dosimetry was realized in the direction of the rectum and bladder. To know the effect of the shielding of the devices type Manchester in the dose, the thermoluminescent dosemeters were irradiated to a radiation gamma source of 192Ir contained in the Gamma med Plus equipment. The planning was realized normalizing the calculation to 2.5 cm from the applicator center on the transverse plane (2.5, 0, 0). The results show that the dose distribution for an ovoid without shielding is more uniform in the transversal plane to the source axis. The results were compared with the calculated results by means of the planning system BrachyVision. While the absorbed dose distribution around an ovoid with shielding is completely anisotropic. This anisotropic is due to the shielding. (Author)

Availability note (English)

Available from the Instituto Nacional de Investigaciones Nucleares, Centro de Informacion y Documentacion Nuclear, 52750 Ocoyoacac, Estado de Mexico (MX), e-mail: javier.ortega@inin.gob.mx; claudio.fernandez@inin.gob.mx;

Additional details

Additional titles

Original title (Spanish)
Determinacion de la dosis alrededor de un ovoide para tratamientos en braquiterapia intracavitaria HDR

Publishing Information

Publisher
Sociedad Mexicana de Seguridad Radiologica A. C.
Imprint Place
Mexico D. F. (Mexico)
Imprint Pagination
9 p.

Conference

Title
toward a continuous improvement of the radiological protection in Mexico
Original Conference Title
12. Congreso Nacional: hacia una mejora continua de la proteccion radiologica en Mexico
Acronym
12. National Congress
Dates
11-13 Nov 2009
Place
San Luis Potosi, SLP (Mexico)