Published June 1, 1980 | Version v1
Journal article

Multistage time averaging filters for timing measurements with large counters

  • 1. Argonne National Lab., IL (USA). High Energy Physics Div.

Description

A method is described which uses multistage logic circuitry to accurately determine the 'true time' that a particle traverses as long counter essentially independent of the 'hit' position. The accuracy increases rapidly with the number of stages used in the circuit. Several channels of the simplest type with about +-70 ps resolution over a total range of 4.2 ns habe been built, tested and used successfully in experiment E450 at the ZGS. (orig.)

Additional details

Publishing Information

Journal Title
Nucl. Instrum. Methods
Journal Volume
172
Journal Issue
3
Series
Nucl. Instrum. Methods.
Journal Page Range
491-499
ISSN
0029-554X

INIS

Country of Publication
Netherlands
Country of Input or Organization
Netherlands
INIS RN
13651189
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Descriptors DEI
COUNTING TECHNIQUES; ELECTRIC FILTERS; RADIATION DETECTORS; TIME RESOLUTION; TIMING CIRCUITS
Descriptors DEC
ELECTRONIC CIRCUITS; FILTERS; MEASURING INSTRUMENTS; RESOLUTION; TIMING PROPERTIES