Published January 1982 | Version v1
Journal article

An improved method for the radioimmunoassay of free-thyroxine in serum dialysates

Creators

  • 1. 9050386GB:Amersham International Ltd., Amersham (UK)

Description

A convenient, sensitive radioimmunoassay (using 125I) of free thyroxine in serum dialysates is described. The method utilizes a solid phase separation system (pre-formed double antibody) and a relatively short incubation period (220 min) with a staggered addition of tracer. Blanks were low and consistent. The normal range for non-pregnant euthyroid samples (n = 59) was 11-23 pmol/l. Third trimester pregnancy samples were mostly within the normal range but at the lower end. Patients on T4 replacement showed a much wider variation in free T4 levels with many samples in the hyperthyroid region. Some hypothyroid samples had undetectable free T4 levels and hyperthyroid samples were frequently greater than 80 pmol/l. (author)

Additional details

Publishing Information

Journal Title
Clin. Endocrinol.
Journal Volume
16
Journal Issue
1
Series
Clin. Endocrinol.
Journal Page Range
101-105
ISSN