Published February 1988 | Version v1
Journal article

Trace characterization of tantalum by NAA involving pre- and post-irradiation separations

  • 1. Ulm Univ. (Germany, F.R.). Sektion Analytik und Hoechstreinigung

Description

Three different methods for pre-irradiation separation of the tantalum matrix combined with preconcentration of trace elements for NAA were developed. They involve selective extraction of tantalum with diantipyrylmethane, and anion- and cation-exchange from hydrofluoric acid medium. The role of the blank as the limiting factor for limits of detection and accuracy was one of the main aspects of this investigation. A conventional radiochemical NAA was also applied. The trace elements considered were Ag,Ba,Ce,Co,Cr,Cu,Eu,Hf,K,La,Mn,Mo,Na,Rb,Re,Sc,W,Y,Zn,Zr. The methods were used for the analysis of tantalum materials of different purity grades. The advantages and disadvantages of each technique are discussed and the achievable limits of detection are given. (author) 26 refs.; 4 figs.; 4 tabs

Additional details

Publishing Information

Journal Title
J. Radioanal. Nucl. Chem.
Journal Volume
120
Journal Issue
2
Series
J. Radioanal. Nucl. Chem. ;Articles.
Journal Page Range
319-333
ISSN
0236-5731
CODEN
JRNCD