Treatment planning considerations of reshapeable automatic intensity modulator for intensity modulated radiation therapy
- 1. Department of Radiological Sciences, Medical Sciences 1, B-140, University of California, Irvine, California 92697 (United States)
- 2. Department of Radiation Oncology, University of California, Irvine, California 92697 (United States)
- 3. Department of Radiological Sciences, University of California, Irvine, California 92697 (United States)
Description
As compared with multi-leaf collimator based intensity modulated radiation therapy (IMRT) techniques, physical modulators have the major advantage of temporally invariant intensity map delivery which makes it more flexible with monitor unit rate, simpler resolution of interrupted treatment and easier implementation and use with respiratory gating. However, traditional physical modulator techniques require long fabrication time and operator intervention during treatments. It has been previously proposed [Xu et al., Med. Phys. 29, 2222-2229 (2002)] that a reshapeable automatic intensity modulator (RAIM) can automatically produce physical modulators by molding a deformable high x-ray attenuation material using a matrix of computer-controlled pistons. RAIM can potentially eliminate the limitations of traditional physical modulators. The present study addresses the treatment planning considerations of RAIM for IMRT. In this study, a 3D treatment-planning system (PLUNC) was modified to include the capability of providing treatment planning using RAIM. Two clinically representative cases were studied: nasopharyngeal and prostate tumors. First, the RAIM system with two different spatial resolutions at isocenter, 1x1 cm2 and 0.5x0.5 cm2, were evaluated. The treatment planning results of RAIM were then compared with other IMRT techniques such as smooth modulator with ideal (100%-2%) and limited (100%-13%) intensity modulation ranges, segmental multi-leaf collimator (SMLC) with ten intensity levels, 1 cm leaf width and 0.5 cm step size and serial tomotherapy using the Peacock registered system. Bringing the spatial resolution of RAIM down to 0.5x0.5 cm2 did not show improvement due to the effect of penumbra. The RAIM system with 1x1 cm2 proved slightly inferior as compared to the ideal smooth physical modulator but better than the SMLC technique and the smooth modulator with limited modulation range. When compared to serial tomotherapy, RAIM is only inferior in brain stem sparing for the nasopharynx case. Furthermore, the RAIM system with 1x1 cm2 resolution required significantly lower monitor units as compared to the other IMRT techniques for the two cases studied
Additional details
Identifiers
- DOI
- 10.1118/1.1774112;
Publishing Information
- Journal Title
- Medical Physics
- Journal Volume
- 31
- Journal Issue
- 8
- Journal Page Range
- p. 2344-2355
- ISSN
- 0094-2405
- CODEN
- MPHYA6
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 36002455
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ATTENUATION; BRAIN; CARCINOMAS; COLLIMATORS; PHARYNX; PROSTATE; RADIOTHERAPY; SPATIAL RESOLUTION
- Descriptors DEC
- BODY; CENTRAL NERVOUS SYSTEM; DIGESTIVE SYSTEM; DISEASES; GLANDS; MALE GENITALS; MEDICINE; NEOPLASMS; NERVOUS SYSTEM; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; RESOLUTION; RESPIRATORY SYSTEM; THERAPY
Optional Information
- Notes
- (c) 2004 American Association of Physicists in Medicine.