Metrological characterization of X-ray diffraction methods at different acquisition geometries for determination of crystallite size in nano-scale materials

Description

Crystallite size values were determined by X-ray diffraction methods for 183 powder samples. The tested size range was from a few to about several hundred nanometers. Crystallite size was calculated with direct use of the Scherrer equation, the Williamson–Hall method and the Rietveld procedure via the application of a series of commercial and free software. The results were statistically treated to estimate the significance of the difference in size resulting from these methods. We also estimated effect of acquisition conditions (Bragg–Brentano, parallel-beam geometry, step size, counting time) and data processing on the calculated crystallite size values. On the basis of the obtained results it is possible to conclude that direct use of the Scherrer equation, Williamson–Hall method and the Rietveld refinement employed by a series of software (EVA, PCW and TOPAS respectively) yield very close results for crystallite sizes less than 60 nm for parallel beam geometry and less than 100 nm for Bragg–Brentano geometry. However, we found that despite the fact that the differences between the crystallite sizes, which were calculated by various methods, are small by absolute values, they are statistically significant in some cases. The values of crystallite size determined from XRD were compared with those obtained by imaging in a transmission (TEM) and scanning electron microscopes (SEM). It was found that there was a good correlation in size only for crystallites smaller than 50 – 60 nm. Highlights: • The crystallite sizes for 183 nanopowders were calculated using different XRD methods • Obtained results were subject to statistical treatment • Results obtained with Bragg-Brentano and parallel beam geometries were compared • Influence of conditions of XRD pattern acquisition on results was estimated • Calculated by XRD crystallite sizes were compared with same obtained by TEM and SEM

Availability note (English)

Available from http://dx.doi.org/10.1016/j.matchar.2013.09.002

Additional details

Identifiers

DOI
10.1016/j.matchar.2013.09.002;
PII
S1044-5803(13)00255-6;

Publishing Information

Journal Title
Materials Characterization
Journal Volume
85
Journal Page Range
p. 111-123
ISSN
1044-5803
CODEN
MACHEX

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
45110124
Subject category
S36: MATERIALS SCIENCE;
Descriptors DEI
COMPUTER CODES; GEOMETRY; MATERIALS; NANOSTRUCTURES; SCANNING ELECTRON MICROSCOPY; TRANSMISSION ELECTRON MICROSCOPY; X-RAY DIFFRACTION
Descriptors DEC
COHERENT SCATTERING; DIFFRACTION; ELECTRON MICROSCOPY; MATHEMATICS; MICROSCOPY; SCATTERING

Optional Information

Copyright
Copyright (c) 2013 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.