Published December 2008
| Version v1
Journal article
Aging management of steam generator in Qinshan nuclear power plant
Description
According to the principle of PDCA cycle in SG aging management, this paper explains the establishment of aging management system, the operation and control(mainly water chemistry control), and the check, inspection, evaluation and maintenance of steam generator (SG) in Qinshan Nuclear Power Plant (QNPP). With the implementation of these measures, the aging and degradation of SG in QNPP are managed effectively. The SG of QNPP are still in good condition after 16-years of operation. (authors)
Additional details
Publishing Information
- Journal Title
- Nuclear Power Engineering
- Journal Volume
- 29
- Journal Issue
- 6
- Journal Page Range
- p. 115-118
- ISSN
- 0258-0926
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 43075288
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- AGING; CONTROL; EVALUATION; IMPLEMENTATION; INSPECTION; MAINTENANCE; MANAGEMENT; NUCLEAR POWER PLANTS; OPERATION; PWR TYPE REACTORS; QINSHAN-1 REACTOR; SERVICE LIFE; STEAM GENERATORS; WATER CHEMISTRY
- Descriptors DEC
- BOILERS; CHEMISTRY; ENRICHED URANIUM REACTORS; LIFETIME; NUCLEAR FACILITIES; POWER PLANTS; POWER REACTORS; PWR TYPE REACTORS; REACTORS; THERMAL POWER PLANTS; THERMAL REACTORS; VAPOR GENERATORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- 1 fig., 1 tab.