Published January 1989 | Version v1
Journal article

Experience of baffle cooling on 36 inches diffusion pump in the main vac system of VEC

Creators

  • 1. Indian Society of Earthquake Technology, Roorkee (India)

Description

Cyclotron Resonator and 'D' tanks are evacuated by two nos. 89 cm diffusion pumps operating in parallel. Cooled chevron baffles are placed on the top of diffusion pumps to prevent back-streaming and back-migration of DP oil into the cyclotron chamber. At present baffles are cooled by 2 stage cascade system freon units which attain a temp of -40deg in the baffles. It is thought that lower temp in the baffle will reduce oil migration. Passing of liquid nitrogen through the baffles was ruled out for technical and economical reasons. Alternatively, cryocoolers attaining temp of -100degC are being explored for the job. (author). 3 figs

Additional details

Publishing Information

Journal Title
Indian Journal of Physics, Part A
Journal Volume
63
Journal Issue
1
Series
Indian J. Phys., Part A.
Journal Page Range
1-4
ISSN
0252-9262
CODEN
INJAD

Conference

Title
Seminar on physics and technology of particle accelerators and their applications.
Dates
29 Jan - 3 Feb 1987.
Place
Calcutta (India).

INIS

Country of Publication
India
Country of Input or Organization
India
INIS RN
20057059
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BAFFLES; CALCUTTA CYCLOTRON; COST ESTIMATION; FREONS; REFRIGERATION; VACUUM PUMPS; VACUUM SYSTEMS
Descriptors DEC
ACCELERATORS; CONTROL EQUIPMENT; COOLING; CYCLIC ACCELERATORS; CYCLOTRONS; EQUIPMENT; FLOW REGULATORS; HEAVY ION ACCELERATORS; ORGANIC COMPOUNDS; ORGANIC HALOGEN COMPOUNDS; PUMPS