Published October 15, 1980 | Version v1
Report Open

The Combined Action of Pressure Vessel Failure, Amoeba Effect and SiC-Corrosion in the Experiments BR2-P21 and BR2-P22

Description

The irradiation of (Th,U)O2 LTI Triso fuels (Table 1) to 10 % FIMA and fast fluence 14 x 1021 cm-2 (E> 0.1 MeV) at temperatures between 1100 and 1600°C and temperature gradients up to near 600°C/cm (Table 2) has shown the three classical failure phenomena 1. pressure vessel failure 2. amoeba effect 3. SiC-corrosion

Files

52022249.pdf

Files (543.9 kB)

Name Size Download all
md5:aef1dc505a73beb07cf9f4f7d4836b5c
543.9 kB Preview Download

System files (10.6 kB)

Name Size Download all

Additional details

Publishing Information

Imprint Pagination
13 p.
Report number
KFA-HBK-TN--14/80

Optional Information

Notes
Document from Juelich Preservation Project; 7 figs., 3 tabs.