Published August 8, 2013 | Version v1
Journal article

Measurement of the muon-induced neutron yield in liquid scintillator and stainless steel at LNGS with the LVD experiment

  • 1. University of Bologna and INFN-Bologna, Bologna (Italy)

Description

We describe the measurement of the muon-induced neutron yield in liquid scintillator and stainless steel (SS) at the Gran Sasso National Laboratory (LNGS), with the LVD experiment. The Large Volume Detector (LVD) is located in Hall A of the LNGS and is made of 1000 t of liquid scintillator and 1000 t of SS. Using an independent measurement to evaluate the background and with the support of a full Monte Carlo simulation based on Geant4, we measured a neutron yield of (2.9±0.6)×10−4 and (1.5±0.3)×10−3 in liquid scintillator and in stainless steel, respectively

Additional details

Identifiers

Publishing Information

Journal Title
AIP Conference Proceedings
Journal Volume
1549
Journal Issue
1
Journal Page Range
p. 235-238
ISSN
0094-243X
CODEN
APCPCS

Conference

Title
4. international workshop on low radioactivity techniques
Acronym
LRT 2013
Dates
10-12 Apr 2013
Place
Assergi (Italy)

Optional Information

Notes
(c) 2013 AIP Publishing LLC
Collaborations
LVD Collaboration