Published 1992 | Version v1
Book

High power density, thin magnetic D.C. septa for AmPS

  • 1. Nationaal Inst. voor Kernfysica en Hoge-Energiefysica (NIKHEF), Amsterdam (Netherlands)

Description

Both the injection and extraction line of the Amsterdam Pulse Stretcher ring (AmPS) contain a d.c. septum magnet. The 400 mm long injection septum, located inside the ring vacuum, requires 1075 A in its winding to generate the maximum field of 0.135 T. The 700 mm long extraction septum is outside the vacuum and consists of 2 turns to generate a maximum field of 0.271 T at 2160 A. The injection septum directs the beam parallel to the ring axis by a downward bend. The magnetic extraction septum bends the extracted beam, initially intercepted and separated from the circulating beam by the electrostatic extraction septum. (R.P.) 8 refs.; 5 figs

Part of:
Proceedings of the 3. European particle accelerator conference. V. 2

Additional details

Publishing Information

Publisher
Editions Frontieres.
Imprint Place
Paris (France)
ISBN
2-86332-115-3
Imprint Title
Proceedings of the 3. European particle accelerator conference. V. 2
Imprint Pagination
[941 p.].
Journal Page Range
p. 1478-1480.

Conference

Title
3. European particle accelerator conference.
Acronym
EPAC 92
Dates
24-28 Mar 1992.
Place
Berlin (Germany).

INIS

Country of Publication
France
Country of Input or Organization
France
INIS RN
24054310
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BEAM EXTRACTION; BEAM INJECTION; BEAM OPTICS; ELECTROSTATIC SEPTA; PULSE SHAPERS; SEPTUM MAGNETS; STORAGE RINGS
Descriptors DEC
ELECTRONIC CIRCUITS; EQUIPMENT; MAGNETS; PULSE CIRCUITS