Published 1984 | Version v1
Report Restricted

Scaling of heavy ion beam probes for reactor-size devices

Description

Heavy ion beam probes for reactor-size plasma devices will require beam energies of approximately 10 MeV. Although accelerator technology appears to be available, beam deflection systems and parallel plate energy analyzers present severe difficulties if existing technology is scaled in a straightforward manner. We propose a different operating mode which will use a fixed beam trajectory and multiple cylindrical energy analyzers. Development effort will still be necessary, but we believe the basic technology is available

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01 as DE85006864.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
9 p.
Report number
DOE/ET/53004--75

Conference

Title
5. APS topical conference on high temperature plasma diagnostics.
Dates
16-20 Sep 1984.
Place
Tahoe City, CA (USA).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
16062412
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ELECTROSTATIC ANALYZERS; HEAVY IONS; ION BEAMS; PLASMA DIAGNOSTICS; PROBES; SCALING LAWS; THERMONUCLEAR REACTORS
Descriptors DEC
BEAM ANALYZERS; BEAMS; CHARGED PARTICLES; IONS

Optional Information

Secondary number(s)
CONF-840922--21; RPDL--84-47.