Published June 21, 2024 | Version v1
Journal article

Antineutrino flux from the EDF Hartlepool nuclear power plant

Description

In this paper, we present a detailed simulation of the antineutrino emissions from an advanced gas-cooled reactor (AGR) core, benchmarked with input data from the United Kingdom Hartlepool reactors. An accurate description of the evolution of the antineutrino spectrum of reactor cores is needed to assess the performance of antineutrino-based monitoring concepts for nonproliferation, including estimations of the sensitivity of the antineutrino rate and spectrum to fuel content and reactor thermal power. The antineutrino spectral variation we present, while specific to AGRs, are different from studies published previously and help provide insight into the likely behavior of other reactor designs that use a similar refueling approach, such as those used in the RBMK ( – "high-power channel-type reactor"), CANDU (Canada Deuterium Uranium), and other reactors.