Published July 2006
| Version v1
Miscellaneous
Numerical simulation of thermal stratification in a branch pipe
- 1. Toshiba Corp., Yokoyama, Kanagawa (Japan)
Description
The cavity flow is driven by the main flow where the branched flow from main pipe in plants is stagnant. Heat of main flow is transported to the branch pipe and the thermal stratification is formed in the branch pipe. It is necessary that the location of thermal stratification can be predicted in order to estimate the thermal fatigue of pipe wall. This study predicts the location of thermal stratification using numerical simulation, and showed the prediction has good agreement with experiments. (author)
Additional details
Additional titles
- Original title (Japanese)
- Nippon hozen gakkai dai-3-kai gakujutsu koenkai yoshishu
Publishing Information
- Imprint Title
- Proceedings of the 3rd annual meeting of Japan Society of Maintenology
- Imprint Pagination
- 405 p.
- Journal Page Range
- p. 87-88
Conference
- Title
- 3. annual meeting of Japan Society of Maintenology
- Dates
- 6-7 Jul 2006
- Place
- Sendai, Miyagi (Japan)
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 42010930
- Subject category
- S42: ENGINEERING;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- FLUCTUATIONS; JOINTS; NUCLEAR POWER PLANTS; NUMERICAL ANALYSIS; PIPES; REYNOLDS NUMBER; STRATIFICATION; TEMPERATURE DISTRIBUTION; THERMAL FATIGUE; THERMAL HYDRAULICS; VELOCITY; VORTEX FLOW
- Descriptors DEC
- DIMENSIONLESS NUMBERS; FATIGUE; FLUID FLOW; FLUID MECHANICS; HYDRAULICS; MATHEMATICS; MECHANICAL PROPERTIES; MECHANICS; NUCLEAR FACILITIES; POWER PLANTS; THERMAL POWER PLANTS; TUBES; VARIATIONS
Optional Information
- Notes
- 3 refs., 4 figs., 2 tabs. Imprint:Nippon hozen gakkai dai-3-kai gakujutsu koenkai yoshishu