Numerical simulation of thermal stratification in a branch pipe

  • 1. Toshiba Corp., Yokoyama, Kanagawa (Japan)

Description

The cavity flow is driven by the main flow where the branched flow from main pipe in plants is stagnant. Heat of main flow is transported to the branch pipe and the thermal stratification is formed in the branch pipe. It is necessary that the location of thermal stratification can be predicted in order to estimate the thermal fatigue of pipe wall. This study predicts the location of thermal stratification using numerical simulation, and showed the prediction has good agreement with experiments. (author)

Part of:
Proceedings of the 3rd annual meeting of Japan Society of Maintenology

Additional details

Additional titles

Original title (Japanese)
Nippon hozen gakkai dai-3-kai gakujutsu koenkai yoshishu

Publishing Information

Imprint Title
Proceedings of the 3rd annual meeting of Japan Society of Maintenology
Imprint Pagination
405 p.
Journal Page Range
p. 87-88

Conference

Title
3. annual meeting of Japan Society of Maintenology
Dates
6-7 Jul 2006
Place
Sendai, Miyagi (Japan)

INIS

Country of Publication
Japan
Country of Input or Organization
Japan
INIS RN
42010930
Subject category
S42: ENGINEERING;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
FLUCTUATIONS; JOINTS; NUCLEAR POWER PLANTS; NUMERICAL ANALYSIS; PIPES; REYNOLDS NUMBER; STRATIFICATION; TEMPERATURE DISTRIBUTION; THERMAL FATIGUE; THERMAL HYDRAULICS; VELOCITY; VORTEX FLOW
Descriptors DEC
DIMENSIONLESS NUMBERS; FATIGUE; FLUID FLOW; FLUID MECHANICS; HYDRAULICS; MATHEMATICS; MECHANICAL PROPERTIES; MECHANICS; NUCLEAR FACILITIES; POWER PLANTS; THERMAL POWER PLANTS; TUBES; VARIATIONS

Optional Information

Notes
3 refs., 4 figs., 2 tabs. Imprint:Nippon hozen gakkai dai-3-kai gakujutsu koenkai yoshishu