LV wall segmentation using the variational level set method (LSM) with additional shape constraint for oedema quantification
Creators
- 1. Department of Electronic and Electrical, Centre for Excellence in Signal and Image Processing, University of Strathclyde, Glasgow (United Kingdom)
- 2. Faculty of Medicine, BHF Cardiovascular Research Centre, University of Glasgow, Glasgow (United Kingdom)
Description
In this paper an automatic algorithm for the left ventricle (LV) wall segmentation and oedema quantification from T2-weighted cardiac magnetic resonance (CMR) images is presented. The extent of myocardial oedema delineates the ischaemic area-at-risk (AAR) after myocardial infarction (MI). Since AAR can be used to estimate the amount of salvageable myocardial post-MI, oedema imaging has potential clinical utility in the management of acute MI patients. This paper presents a new scheme based on the variational level set method (LSM) with additional shape constraint for the segmentation of T2-weighted CMR image. In our approach, shape information of the myocardial wall is utilized to introduce a shape feature of the myocardial wall into the variational level set formulation. The performance of the method is tested using real CMR images (12 patients) and the results of the automatic system are compared to manual segmentation. The mean perpendicular distances between the automatic and manual LV wall boundaries are in the range of 1–2 mm. Bland–Altman analysis on LV wall area indicates there is no consistent bias as a function of LV wall area, with a mean bias of −121 mm2 between individual investigator one (IV1) and LSM, and −122 mm2 between individual investigator two (IV2) and LSM when compared to two investigators. Furthermore, the oedema quantification demonstrates good correlation when compared to an expert with an average error of 9.3% for 69 slices of short axis CMR image from 12 patients. (paper)
Availability note (English)
Available from http://dx.doi.org/10.1088/0031-9155/57/19/6007Additional details
Identifiers
Publishing Information
- Journal Title
- Physics in Medicine and Biology
- Journal Volume
- 57
- Journal Issue
- 19
- Journal Page Range
- p. 6007-6023
- ISSN
- 0031-9155
- CODEN
- PHMBA7
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 44049848
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ALGORITHMS; HEALTH HAZARDS; IMAGES; MYOCARDIAL INFARCTION; NMR IMAGING; PATIENTS; PERFORMANCE; VARIATIONAL METHODS
- Descriptors DEC
- CALCULATION METHODS; CARDIOVASCULAR DISEASES; DIAGNOSTIC TECHNIQUES; DISEASES; HAZARDS; MATHEMATICAL LOGIC