Published 2013 | Version v1
Miscellaneous Open

Tissue quantification for development of pediatric phantom

  • 1. Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Dept. de Fisica e Biofisica. Inst. de Biociencias de Botucatu
  • 2. Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Fac. de Medicina de Botucatu. Dept. de Doencas Tropicais e Diagnostico por Imagem

Description

The optimization of the risk- benefit ratio is a major concern in the pediatric radiology, due to the greater vulnerability of children to the late somatic effects and genetic effects of exposure to radiation compared to adults. In Brazil, it is estimated that the causes of death from head trauma are 18 % for the age group between 1-5 years and the radiograph is the primary diagnostic test for the detection of skull fracture . Knowing that the image quality is essential to ensure the identification of structures anatomical and minimizing errors diagnostic interpretation, this paper proposed the development and construction of homogeneous phantoms skull, for the age group 1-5 years. The construction of the phantoms homogeneous was performed using the classification and quantification of tissue present in the skull of pediatric patients. In this procedure computational algorithms were used, using Matlab, to quantify distinct biological tissues present in the anatomical regions studied , using pictures retrospective CT scans. Preliminary data obtained from measurements show that between the ages of 1-5 years, assuming an average anteroposterior diameter of the pediatric skull region of the 145.73 ± 2.97 mm, can be represented by 92.34 mm ± 5.22 of lucite and 1.75 ± 0:21 mm of aluminum plates of a provision of PEP (Pacient equivalent phantom). After its construction, the phantoms will be used for image and dose optimization in pediatric protocols process to examinations of computerized radiography

Files

44128244.pdf

Files (137.2 kB)

Name Size Download all
md5:10475b1ec8288e60d9239edc706b9ad6
137.2 kB Preview Download

Additional details

Additional titles

Original title (Portuguese)
Quantificacao de tecidos para desenvolvimento de fantoma pediatrico

Publishing Information

Imprint Pagination
7 p.
Report number
INIS-BR--13026

Conference

Title
9. Regional Congress of IRPA on radiological and nuclear safety; 5. Iberoamerican Congress of the Radiological Protection Societies; 3. Brazilian Congress on radiological protection
Original Conference Title
9. Congresso regional IRPA de seguridade radiologica y nuclear. 5. Congresso iberoamericano de sociedades de proteccion radiologica. 3. Congresso brasileiro de proteccion radiologica
Dates
14-19 Apr 2013
Place
Rio de Janeiro, RJ (Brazil)

INIS

Country of Publication
Brazil
Country of Input or Organization
Brazil
INIS RN
44128244
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ALGORITHMS; ANIMAL TISSUES; COMPUTERIZED TOMOGRAPHY; OPTIMIZATION; PEDIATRICS; PHANTOMS; RADIATION DOSES; SKULL
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; DOSES; MATHEMATICAL LOGIC; MEDICINE; MOCKUP; ORGANS; SKELETON; STRUCTURAL MODELS; TOMOGRAPHY