Seismic margin of the piping of the active and passive systems of the emergency core cooling system at the Dukovany-1 reactor unit. Pt. 1: Piping

Description

The seismic margin was determined for pipes of the high-pressure ECCS of loops 2, 3, and 5, low-pressure ECCS of loop 4, and piping of the passive core flooding system; the treatment was limited to the part within the hermetic zone

Availability note (English)

Available from Nuclear Research Institute Rez, 250 68 Rez, Czech Republic; e-mail contact: ret@nri.cz

Additional details

Additional titles

Original title (Czech)
Mezni seismicka odolnost potrubi pasivnich a aktivnich systemu havarijniho chlazeni aktivni zony EDU, blok 1. Cast 1: Potrubi

Publishing Information

Imprint Pagination
45 p.
Report number
UJV--11107-T

Optional Information

Notes
10 tabs., 31 figs., 4 refs.