Published March 11, 2011 | Version v1
Journal article

Calibration of the ISOLDE acceleration voltage using a high-precision voltage divider and applying collinear fast beam laser spectroscopy

  • 1. Institut fuer Kernchemie, Johannes Gutenberg, Universitaet Mainz, Fritz-Strassmann-Weg 2, 55128 Mainz (Germany)
  • 2. GSI Helmholtzzentrum fuer Schwerionenforschung, 64291 Darmstadt (Germany)
  • 3. CERN, CH-1211 Geneve 23 (Switzerland)
  • 4. Institut fuer Kernphysik, Universitaet Muenster, 48149 Muenster (Germany)
  • 5. Max-Planck-Institut fuer Kernphysik, 69117 Heidelberg (Germany)

Description

A high-voltage divider with accuracy at the ppm level and collinear laser spectroscopy were used to calibrate the high-voltage installation at the radioactive ion beam facility ISOLDE at CERN. The accurate knowledge of this voltage is particularly important for collinear laser spectroscopy measurements. Beam velocity measurements using frequency-comb based collinear laser spectroscopy agree with the new calibration. Applying this, one obtains consistent results for isotope shifts of stable magnesium isotopes measured using collinear spectroscopy and laser spectroscopy on laser-cooled ions in a trap. The long-term stability and the transient behavior during recovery from a voltage dropout were investigated for the different power supplies currently applied at ISOLDE.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.nima.2010.12.145

Additional details

Identifiers

DOI
10.1016/j.nima.2010.12.145;
arXiv
arXiv:1101.2536v1;
PII
S0168-9002(10)02925-6;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
632
Journal Issue
1
Journal Page Range
p. 23-31
ISSN
0168-9002
CODEN
NIMAER

Optional Information

Copyright
Copyright (c) 2010 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.