B-10 lined proportional counters for thermal neutron flux monitoring at the nuclear reactors have been developed. Design details of the counters with thermal neutron sensitivity of 20 cps/nv and 1 cps/nv are described. Systematic tests carried out on the detectors establish the usefulness for the reactor applications. The gas constants for the boron counter gas mixture 95% A + 5% CO2 have been evaluated. These values are extremely useful in estimation of the amplification factor for the boron lined counters at various operating parameters. The gamma tolerances of the detectors have been estimated experimentally. (author)
Additional details
Publishing Information
- Publisher
- Dept. of Atomic Energy
- Imprint Place
- Mumbai (India)
- ISBN
- 81-88513-33-4
- Imprint Title
- Proceedings of DAE-BRNS national symposium on nuclear instrumentation - 2010
- Imprint Pagination
- 679 p.
- Journal Page Range
- p. 302-306
Conference
- Title
- national symposium on nuclear instrumentation
- Acronym
- NSNI 2010
- Dates
- 24-26 Feb 2010
- Place
- Mumbai (India)
INIS
- Country of Publication
- India
- Country of Input or Organization
- India
- INIS RN
- 41082260
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BORON LINED COUNTERS; NEUTRON FLUX; PERFORMANCE TESTING; REACTOR CORES; SPECIFICATIONS
- Descriptors DEC
- MEASURING INSTRUMENTS; NEUTRON DETECTORS; PROPORTIONAL COUNTERS; RADIATION DETECTORS; RADIATION FLUX; REACTOR COMPONENTS; TESTING
Optional Information
- Notes
- 9 figs., 2 tabs.