Published September 2013 | Version v1
Journal article

Computation method modification for MCNP program on direct contribution of mono-directional surface source

  • 1. Institute of Applied Physics and Computational Mathematics, Beijing (China)

Description

Point detector flux estimation method is widely applied in the model that volume of detected region is far smaller than that of system. Because of some bug in MCNP5 code on calculating the direct contribution from mono-directional surface source, the result of point detector flux usually differs from that of cell flux. Moreover, the direct contribution of mono-directional surface source is computed repeatedly in MCNP program which includes MCNP5 and MCNP4C, so the computation efficiency is very low. A simplified method was introduced in this paper, and the efficiency is greatly increased. (authors)

Additional details

Publishing Information

Journal Title
Atomic Energy Science and Technology
Journal Volume
47
Journal Issue
9
Journal Page Range
p. 1488-1491
ISSN
1000-6931

INIS

Country of Publication
China
Country of Input or Organization
China
INIS RN
46132202
Subject category
S73: NUCLEAR PHYSICS AND RADIATION PHYSICS;
Descriptors DEI
CALCULATION METHODS; EFFICIENCY; M CODES; MODIFICATIONS; NEUTRON FLUX; NEUTRON SOURCES; SURFACES
Descriptors DEC
COMPUTER CODES; PARTICLE SOURCES; RADIATION FLUX; RADIATION SOURCES

Optional Information

Notes