Low prepulse, high power density water dielectric switching
Description
Prepulse voltage suppression has proven difficult in high power, high voltage accelerators employing self-breakdown water dielectric switches. A novel and cost effective water switch has been developed at Sandia Laboratories which reduces prepulse voltage by reducing the capacity across the switch. This prepulse suppression switch causes energy formerly stored in the switch capacity and dissipated in the arc to be useful output energy. The switching technique also allows the pulse forming lines to be stacked in parallel and electrically isolated from the load after the line has been discharged. The switch consists of a ground plane, with several holes, inserted between the switch electrodes. The output line switch electrodes extend through the holes and face electrodes on the pulse forming line (PFL). The capacity between the PFL and the output transmission line is reduced by about 80%. The gap spacing between the output line electrode and the hole in the ground plane is adjusted so that breakdown occurs after the main pulse and provides a crow bar between the load and the source. Performance data from the Proto II, Mite and Ripple test facilities are presented
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01.Files
10494794.pdf
Files
(123.4 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:eaccece0c331715e4d631a68a6405736
|
123.4 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 3 p.
- Report number
- SAND--79-0718C
Conference
- Title
- Pulsed power conference.
- Dates
- 12 - 14 Jun 1979.
- Place
- Lubbock, TX, USA.
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 10494794
- Subject category
- S43: PARTICLE ACCELERATORS; S42: ENGINEERING;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BREAKDOWN; DIELECTRIC MATERIALS; ELECTRIC CONTROLLERS; HIGH-VOLTAGE PULSE GENERATORS; PERFORMANCE; SURGES; SWITCHES; WATER
- Descriptors DEC
- CONTROL EQUIPMENT; ELECTRICAL EQUIPMENT; ELECTRONIC EQUIPMENT; FUNCTION GENERATORS; HYDROGEN COMPOUNDS; OXYGEN COMPOUNDS; PULSE GENERATORS
Optional Information
- Secondary number(s)
- CONF-790622--4.