Published April 1981 | Version v1
Report Open

Iodine dosage by differential attenuation of X-rays emitted by Cs 131

Description

This document presents the study that lead to the development of a method for direct iodine dosage by γ spectrometry. This method called differential attenuation dosage permits the dosage of solutions with concentrations in the range 100 μg.cm-3 - 100 mg.cm-3. In the medical field, several applications are to consider, for example the iodine dosage in vivo of the tyroid

Availability note (English)

MF available from INIS under the Report Number.

Abstract (French)

Ce document rapporte les travaux qui ont conduit au developpement d'un procede de dosage direct de l'iode par spectrometrie γ. Ce procede, appele dosage par attenuation differentielle permet le dosage de solutions de concentration comprise entre 100 μg.cm-3 a 100 mg.cm-3. Dans le domaine medical, plusieurs applications sont envisageables, notamment le dosage de l'iode in vivo au niveau de la thyroide

Files

12628925.pdf

Files (395.0 kB)

Name Size Download all
md5:e485ce20607e96ba89f73b640f9d6a22
395.0 kB Preview Download

Additional details

Additional titles

Original title (French)
Dosage de l'iode par attenuation differentielle des raies X emises par le Cs 131

Publishing Information

Imprint Pagination
18 p.
Report number
CEA-N--2210