Published January 1978 | Version v1
Report Open

Measurement of the dynamic response of the materials testing reactor HIFAR

Description

Power transients were initiated in the HIFAR Materials Testing Reactor by altering both the temperature of the primary coolant circuit and the flow rate of the primary coolant. Analysis of the time variation of the reactor power and the D2O temperature provided information about the flow of D2O in the reactor aluminium tank and the time response of the negative power coefficient. The experimental power transients were compared with calculations carried out with the HIDYN code, which combines the neutron kinetics with the primary coolant characteristics. (Author)

Availability note (English)

MF available from INIS under the Report Number.

Files

9383348.pdf

Files (707.4 kB)

Name Size Download all
md5:e1f36c0ef517a0d4e2bd99aa4be46324
707.4 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
38 p.
Report number
AAEC/E--428