Published April 2013 | Version v1
Journal article

Dual-energy CT in the follow-up after endovascular abdominal aortic aneurysm repair

  • 1. Universitaetsklinikum Muenster (Germany). Inst. fuer Klinische Radiologie
  • 2. Universitaetsklinikum Koeln (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik
  • 3. Universitaetsklinikum Muenster (Germany). Klinik fuer Vaskulaere und Endovaskulaere Chirurgie

Description

This study investigates the dual-energy procedure for postoperative CT follow-up scans after endovascularly treated abdominal aortic aneurysms. The procedure is analyzed with respect to its sensitivity and specificity as well as the associated radiation exposure. 51 examinations were carried out on 47 patients between February 2009 and March 2010. For each patient, a non-enhanced, an arterial and a venous scan were conducted, the latter two using the dual-energy technology. Virtual images for the non-enhanced phase were reconstructed from the data taken in the venous phase. Protocol A, the reference standard, consisted of non-enhanced images and images of the arterial and venous phase. In protocol B, standard non-enhanced images were replaced by the reconstructed virtual non-enhanced images. Protocol C consisted only of virtual non-enhanced and 80 kV images taken during the venous phase. All data was anonymized and evaluated by two independent radiologists. For protocol C, sensitivity, specificity, negative and positive predictive values were computed. The effective radiation dosage was determined for each scan. All endoleaks identified in protocol A were found using protocols B and C. For protocol C, the sensitivity and negative predictive value were 100 %, the specificity was 94.1 %, and the positive predictive value was 89.5 %. Compared to protocol A, protocol C reduces the radiation exposure by 62.45 %. A scan protocol consisting of virtual non-enhanced images as well as 80 kV images taken during the venous phase was found to be a reliable alternative method for diagnosing endoleaks, while reducing the radiation exposure by 62.45 %. (orig.)

Additional details

Additional titles

Original title (German)
Dual-Energy CT zur postoperativen Langzeitkontrolle nach endovaskulaer therapierten abdominellen Aortenaneurysmen

Publishing Information

Journal Title
RoeFo - Fortschritte auf dem Gebiete der Roentgenstrahlen und der bildgebenden Verfahren
Journal Volume
185
Journal Issue
4
Journal Page Range
p. 351-357
ISSN
1438-9029
CODEN
RFGNDO