Published November 1997 | Version v1
Report

Radiation parameter monitoring of the irradiation channel of the RVS-3 loop during the FRAMATOME 1 experiment in 1996/1997

Description

The monitoring system serving to measure the neutron fluence rate with self-powered rhodium detectors and the radiative heating on iron with calorimeters is highlighted. The sensor signal transmission routes and instrumentation for their measurement and recording are described. The method of observed data evaluation is characterized and the results of this processing are given for the FRAMATOME 1 experiment, which was carried out on the RVS-3 loop of the LVR-15 reactor in 1996-1997. (author)

Availability note (English)

Available from Nuclear Research Institute Rez, 250 68 Rez, Czech Republic

Additional details

Additional titles

Original title (Czech)
Monitorovani radiacnich parametru ozarovaciho kanalu smycky RVS-3 behem experimentu FRAMATOME 1 v letech 1996-1997

Publishing Information

Imprint Pagination
48 p.
Report number
UJV--11021-R,T

Optional Information

Notes
16 tabs., 30 figs., 7 refs.