Published July 2016 | Version v1
Journal article

Spot size measurement of a flash-radiography source using the pinhole imaging method

  • 1. Key Laboratory of Pulsed Power, Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang (China)

Description

The spot size of the X-ray source is a key parameter of a flash-radiography facility, and is usually quoted as an evaluation of the resolving power. The pinhole imaging technique is applied to measure the spot size of the Dragon-I linear induction accelerator, by which a two-dimensional spatial distribution of the source spot is obtained. Experimental measurements are performed to measure the spot image when the transportation and focusing of the electron beam are tuned by adjusting the currents of solenoids in the downstream section. The spot size of full-width at half maximum and that defined from the spatial frequency at half peak value of the modulation transfer function are calculated and discussed. (authors)

Additional details

Publishing Information

Journal Title
Chinese Physics. C, High Energy Physics and Nuclear Physics
Journal Volume
40
Journal Issue
7
Journal Page Range
[5 p.]
ISSN
1674-1137

Optional Information

Notes
4 figs., 3 tabs., 12 refs.; http://dx.doi.org/10.1088/1674-1137/40/7/076202