Development of a real-time extremity dose monitor for personnel in interventional radiology
- 1. Oita University of Nursing and Health Sciences, Oita (Japan)
- 2. Oita Medical University, Oita (Japan)
Description
Protection of personnel in interventional radiology is one of the most important issues of radiological protection in medicine. Fluoroscopically guided interventional procedures require the operation near X-ray beam, which brings a considerable hand exposure to the operators. For the purpose of effectual control of their extremity doses, we have developed a real-time extremity dose monitor which is worn on a strap around the wrist. The monitor consists of a silicon semiconductor detector, thin lithium battery and a waterproof frame with a four-digit LED display. Experiment was carried out to examine a response of the monitor to diagnostic X-rays. A practical test was also performed to evaluate usability in the actual interventional procedures. In the experiment, the extremity dose monitor was placed on an arm phantom and exposed to diagnostic X-rays. Readings of the monitor were compared to those of Capintec PS-033 shallow chamber. The monitor was highly sensitive to diagnostic X-rays. It showed a linear response down to doses of a few tens of microsieverts. For high dose-rate exposure, however, a slight decrease in the response was observed, about 10% of counting loss for 80 kV, 40 mA X-ray at one meter from the focus. With regard to energy dependence, variation was within 20% for 60 to 100 kV X-rays. The monitor showed a good angular response in general, except lateral geometry facing the far side from a detector center. In the practical test, hand exposures of medical staff were measured with the extremity dose monitor. They were also asked to fill in a questionnaire regarding size and weight of the monitor, clarity of the display and usefulness. The subjects consisted of physicians, technicians and nurses who engaged in angiography, PTCD, CT-biopsy, barium enema and so on. The readings of the monitor were less than 1 mSv in most cases while 93 mSv was recorded in an extreme case due to direct-beam exposure. In some cases, TLD rings were used together with the extremity dose monitor and the measurement results of the both dosimeters agreed well. As to the answers to the questionnaire, the majority were in favor of the monitor though there were negative comments on size and thickness. The above results demonstrate a good performance of the extremity dose monitor. Since the monitor enables personnel to check their extremity doses on a real-time basis, it may be useful for self-control of the exposure. This could lead to the operations for shorter periods of time, which result in dose reduction in interventional radiology for not only medical staff, but also patients. (author)
Additional details
Publishing Information
- Publisher
- Japan Health Physics Society
- Imprint Place
- Tokyo (Japan)
- Imprint Title
- IRPA-10. Proceedings of the 10th international congress of the International Radiation Protection Association on harmonization of radiation, human life and the ecosystem
- Imprint Pagination
- 1 v.
- Journal Page Range
- [6 p.]
Conference
- Title
- 10. international congress of the International Radiation Protection Association
- Acronym
- IRPA-10
- Dates
- 14-19 May 2000
- Place
- Hiroshima (Japan)
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 32007552
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- DOSEMETERS; PERFORMANCE TESTING; PERSONNEL DOSIMETRY; RADIATION PROTECTION; RADIOLOGICAL PERSONNEL; REAL TIME SYSTEMS; SENSITIVITY; SI SEMICONDUCTOR DETECTORS; SPECIFICATIONS; X RADIATION
- Descriptors DEC
- DOSIMETRY; ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; MEASURING INSTRUMENTS; MEDICAL PERSONNEL; PERSONNEL; RADIATION DETECTORS; RADIATIONS; SEMICONDUCTOR DETECTORS; TESTING
Optional Information
- Notes
- This CD-ROM can be used for WINDOWS 95/98/NT, MACINTOSH; Acrobat Reader is included; Data in PDF format, No. T-23-5; P-7-39; 16 refs., 7 figs., 1 tab.