Calculation of the spectra of photons from 6 to 15 MeV emitted by a linac by deconvolution response matrix generated from the gradients depth dose calculated by MCNP simulation
Creators
Description
This paper proposes a technique to significantly improve the accuracy of reconstructed Bremsstrahlung spectra from depth dose data using inverse methods. While traditional approaches directly use depth dose curves, we show the advantage of using the gradient of these data for the reconstruction of spectra.
Additional details
Additional titles
- Original title (Spanish)
- Calculo de los espectros de fotones de 6 y 15 MeV emitidos por un linac mediante la deconvolucion de la matriz respuesta generada a partir de los gradientes de la dosis en profundidad calculadas mediante simulacion MCNP
Publishing Information
- Publisher
- Senda Editorial
- Imprint Place
- Burgos (Spain)
- Imprint Title
- 37 Annual Meeting of Spanish Nuclear Society, Sept 28-30 2011, Burgos, Spain
- Imprint Pagination
- 2380 p.
- Journal Page Range
- 1 p.
Conference
- Title
- 37. Annual Meeting of Spanish Nuclear Society
- Dates
- 28-30 Sep 2011
- Place
- Burgos (Spain)
INIS
- Country of Publication
- Spain
- Country of Input or Organization
- Spain
- INIS RN
- 44059118
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ELECTRON BEAM MELTING; ENGINEERING; MAINTENANCE; MECHANICAL ENGINEERING; MELTING; NUCLEAR MEDICINE; RADIATION PROTECTION; RADIOACTIVE WASTES; RADIOLOGY; REACTOR DISMANTLING
- Descriptors DEC
- DEMOLITION; ENGINEERING; MATERIALS; MEDICINE; MELTING; NUCLEAR MEDICINE; PHASE TRANSFORMATIONS; RADIOACTIVE MATERIALS; WASTES
Optional Information
- Notes
- Imprint:37 Reunion Anual Sociedad Nuclear Espanola, 28-30 Septiembre 2011, Burgos, Espana