Published August 7, 2003 | Version v1
Journal article

Determination of aortic compliance from magnetic resonance images using an automatic active contour model

  • 1. Deutsches Krebsforschungszentrum (dkfz), Abteilung Biophysik und Medizinische Strahlenphysik E0201, Im Neuenheimer Feld 280, D-69120 Heidelberg (Germany)

Description

The possibility of monitoring changes in aortic elasticity in humans has important applications for clinical trials because it estimates the efficacy of plaque-reducing therapies. The elasticity is usually quantified by compliance measurements. Therefore, the relative temporal change in the vessel cross-sectional area throughout the cardiac cycle has to be determined. In this work we determined and compared the compliance between three magnetic resonance (MR) methods (FLASH, TrueFISP and pulse-wave). Since manual outlining of the aortic wall area is a very time-consuming process and depends on an operator's variability, an algorithm for the automatic segmentation of the artery wall from MR images through the entire heart cycle is presented. The reliable detection of the artery cross-sectional area over the whole heart cycle was possible with a relative error of about 1%. Optimizing the temporal resolution to 60 ms we obtained a relative error in compliance of about 7% from TrueFISP (1.0 x 1.0 x 10 mm3, signal-to-noise ratio (SNR) > 12) and FLASH (0.7 x 0.7 x 10 mm3, SNR > 12) measurements in volunteers. Pulse-wave measurements yielded an error of more than 9%. In a study of ten volunteers, a compliance between C = 3 x 10-5 Pa-1 and C = 8 x 10-5 Pa-1 was determined, depending on age. The results of the TrueFISP and the pulse-wave measurements agreed very well with one another (confidence interval of 1 x 10-5 Pa-1) while the results of the FLASH method more clearly deviated from the TrueFISP and pulse-wave (confidence interval of more than 2 x 10-5 Pa-1)

Availability note (English)

Available online at http://stacks.iop.org/0031-9155/48/2391/m31510.pdf or at the Web site for the journal Physics in Medicine and Biology (ISSN 1361-6560) http://www.iop.org/

Additional details

Publishing Information

Journal Title
Physics in Medicine and Biology
Journal Volume
48
Journal Issue
15
Journal Page Range
p. 2391-2404
ISSN
0031-9155
CODEN
PHMBA7

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
35003223
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ALGORITHMS; AORTA; ELASTICITY; NMR IMAGING; SIGNAL-TO-NOISE RATIO
Descriptors DEC
ARTERIES; BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; MATHEMATICAL LOGIC; MECHANICAL PROPERTIES; ORGANS