Published 1990 | Version v1
Report Open

Evaluation of the reliability of the protection system of 1300 MWE PWR'S

  • 1. CEA Centre d'Etudes Nucleaires de Fontenay-aux-Roses, 92 (France). Inst. de Protection et de Surete Nucleaire

Description

An assesment of the reliability of the Digital Integrated Protection System (SPIN) of the 1300 MWe type french reactors has been carried out by treating an example: the emergency shutdown, which can be called upon by several initiating events. The whole chain, from sensors to breakers and control rods, is taken into account. The reliability parameters used for the quantification are evaluated essentially from the experience feedback of french reactors. The not wellknown parameters being the common cause failure rates of electronic components and the efficiency rate of the self-tests, the results of the study are then presented in a parametric form, according to these two factors

Availability note (English)

MF available from INIS under the Report Number.

Files

22034870.pdf

Files (192.7 kB)

Name Size Download all
md5:f9e2a173eea714cd401ae4b864e7610c
192.7 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
13 p.
Report number
CEA-DAS--743

Conference

Title
IAEA specialists' meeting on analysis and experience in control and instrumentation as a decision tool and International working group on nuclear power plant control and instrumentation.
Dates
16-19 Oct 1990.
Place
Arnhem (Netherlands).

INIS

Country of Publication
France
Country of Input or Organization
France
INIS RN
22034870
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ELECTRONIC CIRCUITS; PROBABILISTIC ESTIMATION; PWR TYPE REACTORS; REACTOR PROTECTION SYSTEMS; RELIABILITY; SYSTEM FAILURE ANALYSIS
Descriptors DEC
ENRICHED URANIUM REACTORS; POWER REACTORS; REACTORS; SYSTEMS ANALYSIS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS