Published November 1986 | Version v1
Report Open

Results and interpretation of noise measurements using in-core self powered neutron detector strings at Unit 2 of the Paks Nuclear Power Plant

Description

In-core neutron noise and fuel assembly outlet temperature noise measurements were performed at Unit 2 of Paks Nuclear Power Plant. Characteristics of the reactor and the noise measuring equipment are briefly described. The in-core Rhodium emitter selfpowered neutron detector strings positioned axially above the other show high coherence and linear phase at low frequencies indicating a marked transport effect, not regularly measured in PWRs. The coherence between horizontally placed neutron detectors is small and the phase is zero. A transport effect of different nature is obtained between neutron detectors (in-core and ex-core) and fuel assembly outlet thermocouples. The observed characteristics depend on reactor and fuel assembly power in a way supporting interpretation in terms of coolant density and void content changes and power feedback effects. During routine analysis vibration of 1.1 Hz appeared as a strong peak in the power spectra. The control assembly that was responsible for the observed behaviour could be localized with high certainty. (author)

Availability note (English)

MF available from INIS under the Report Number.

Files

18037620.pdf

Files (871.5 kB)

Name Size Download all
md5:5a3f86e526f3795b4c132446f8192222
871.5 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
29 p.
Report number
KFKI--1986-81/G

Conference

Title
6. Power plant dynamics, control and testing symposium.
Dates
Apr 1986.
Place
Knoxville, TN (USA).

Optional Information

Notes
23 refs.; 18 figs.; 5 tables.