The ISIS target

  • 1. Rutherford-Appleton Laboratory, Oxon (England)

Description

This presentation discusses the two target failures that have occurred, gives the understanding of the causes and indicates the steps being taken to alleviate the problems. At the outset of the design it was understood that the target would have a finite lifetime, due to radiation damage effects, exacerbated by mechanical damage due to thermal cycling and fatigue. Estimates of target lifetime at full intensity are about 2 years for radiation damage swelling and about 10E4 gross thermal excursions. The latter number is the one which gives uncertainty in defining the life of the target, since it is dependent on the reliability of the accelerator and quality of the proton beam. The commissioning of an accelerator system and bringing it up to high beam intensities have their own special problems. There must be protection of components against uncontrolled beam loss, which produces thermal damage, prompt radiation and induced activity. Fast beam trips for beam loss protection, or equipment failures, result in quenches from high temperature in the target which get bigger with increasing beam intensity. But the target itself is a difficult device to make, taking about 12 months to manufacture. Further, changing one is a complex and time consuming task, not without its hazards. There is thus something of a balancing act to bring the accelerator towards specification before the target fails due to thermal cycling fatigue. In the early days of ISIS beam loss protection was the dominant consideration and the target was regarded somewhat as a sacrificial lamb to the goddess of machine reliability. 2 refs., 6 figs

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Title
Proceedings of the 10th meeting of the international collaboration on advanced neutron sources
Imprint Pagination
847 p.
Journal Page Range
p. 12, Paper 6.
Report number
LA-UR--89-2920

Conference

Title
International collaboration on advanced neutron sources (ICANS).
Dates
3-7 Oct 1988.
Place
Los Alamos, NM (USA).

Optional Information

Secondary number(s)
CONF-8810182--32.